Shopping Cart
cFluor® YG584 anti-Human CD 8 (SK1)

cFluor® YG584 anti-Human CD 8 (SK1)

SKU R7-20244
Regular price

$184.00

task_alt Added to cart.
View Cart or Continue shopping.
Description

The SK1 monoclonal antibody binds to human CD8a, a 32-34-kDa type I glycoprotein that forms either as an α/α homodimer α/β heterodimer with its isoform CD8b. CD8 is found on thymocytes, a subset of peripheral blood T cells, majority expressing α/β heterodimer, and NK cells, majority expressing α/α homodimer1. CD8 plays a role in antigen recognition and class I MHC-restricted T cell development. CD8 functions are associated with two domains of CD8a. CD8a ectodomain binding to the α3 domain of MHC class I increases the adhesion between CD8+ T lymphocytes and target cells. The cytoplasmic tail binding to the tyrosine kinase p56lck contributes to signal transduction and T cell activation2,3. The antibody was conjugated to a fluorophore and purified by affinity chromatography.

PRODUCT DETAILS

Clone:                  SK1

Reactivity:         Human, Chimpanzee, Cynomolgus, Pigtailed Macaque, Rhesus, Sooty Mangabey

Format:              cFluor® YG584*

Isotype:               Mouse IgG1, κ

Tested Dilution:  5 μL / test

Application:        Flow Cytometry

Storage:               2-8°C and protected from Light. Do not freeze

Formulation:       Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide and 0.2% BSA (Origin USA)

Data Sheets:       TDS SDS

 

RECOMMENDED USAGE

Each lot of this antibody is quality control tested using flow cytometric analysis. For flow cytometric staining, the suggested use of this reagent is 5 µL per 1 million cells in a staining volume of 100 µL. If whole blood is analyzed, then use 5 µL per 100 µL. It is recommended that users titrate the antibody to obtain the optimal result for their specific application.

 

Please briefly centrifuge the reagent vial before use.

 

Use appropriate personal protective equipment per the product safety data sheet when using this product.

Spectral signature of cFluor® YG584 from a Cytek® Aurora 5 laser system equipped with 355, 405, 488, 561 and 640 nm lasers using CytekAssaySetting.       

 

REFERENCES

  1. Cole DK, et al. 2004. Cell Mol Immunol. 1(2):81-8
  2. Kern Petra S. et al. 1998. Immunity. 519-530
  3. Veillette A. et al. 1988. Cell. 55:301-308

 

These products are for research use only. Not intended for use in diagnostic procedures.

*cFluor™ YG584 is equivalent to CF® 568 manufactured and provided by Biotium, Inc. under an Agreement between Biotium and Cytek (LICENSEE). The manufacture, use, sale, offer for sale, or import of the product is covered by one or more of the patents or pending applications owned or licensed by Biotium. The purchase of this product includes a limited, non-transferable immunity from suit under the foregoing patent claims for using only this amount of product for the purchaser’s own internal research. No right under any other patent claim, no right to perform any patented method, and no right to perform commercial services of any kind, including without limitation reporting the results of purchaser's activities for a fee or other commercial consideration, is conveyed expressly, by implication, or by estoppel.

Shipping
Price calculated at checkout.