Pacific Blue™ Anti-Human CD11b (ICRF44) | Cytek Biosciences
ショッピングカート
Pacific Blue<sup>&trade;</sup> Anti-Human CD11b (ICRF44)

Pacific Blue™ Anti-Human CD11b (ICRF44)

種類 R7-94773
通常価格

お問い合わせ:cytek_japan_ifc@cytekbio.com
task_alt カートに追加されました。
カートを見る または ショッピングを続ける
説明

The mouse monoclonal antibody clone ICRF44 binds to human CD11b, also known as alpha M, α-M, ITGAM/CR3A, or Mac-1. This 165-170 kDa cell surface glycoprotein is part of a family of integrin α-receptors that mediate adhesion between cells (cell-cell) and components of the extracellular matrix, e.g., fibrinogen (cell-matrix). In addition, integrin α's are active signaling receptors that recruit leukocytes to inflammatory sites and promote cell activation. Complete, functional integrin α-receptors consist of distinct combinations of integrin α-chains, which are differentially expressed. integrin alpha M (CD11b) assembles with integrin beta-2 (CD18) into a receptor known as Macrophage Antigen-1 (Mac-1) or complement receptor type 3 (CR3). This receptor binds and induces intracellular signaling through ICAM-1, ICAM-2, ICAM-3, and ICAM-4 on endothelial cells and can also facilitate the removal of iC3b-bearing foreign cells. CD11b is expressed on many cell types, including myeloid-lineage cells such as monocytes/macrophages, neutrophils, eosinophils, and basophils, and in lymphoid cells such as NK cells, peritoneal B-1 cells, Memory B cells, and microglia.


PRODUCT DETAILS

Clone: ICRF44

Specificity: CD11b

Reactivity: Human, Baboon, Chimpanzee, Cynomolgus Monkey, Rhesus Macaque, Pig

Format: Pacific Blue™

Isotype: Mouse IgG1, k

Tested Dilution: 5 µL/Test

Application: FC

Storage: 2-8°C protected from light.Do not freeze

Formulation: Stabilizing phosphate buffered saline (PBS), pH 7.4, 15 mM sodium azide

Data Sheets: TDS | SDS


RECOMMENDED USAGE

Flow cytometry: The suggested use of this reagent is 5 µL per 1 million cells in a staining volume of 100 µL. If whole blood is analyzed, then use 5 µL per 100 µL. It is recommended that users titrate the antibody to obtain the optimal result for their specific application. The content of a vial (0.5 mL) is sufficient for 100 tests.



REFERENCES

  1. Knapp W. 1989. Leucocyte Typing IV. Oxford University Press New York.
  2. Barclay N, et al. 1997. The Leucocyte Antigen Facts Book. Academic Press Inc. San Diego.
  3. Marsik C, et al. 2003. Shock 20:493-6.
  4. Yoshino N, et al. 2000. Exp. Anim. (Tokyo) 49:97-100.

For research use only. Not intended for use in diagnostic procedures.


“Pacific Blue“ is a trademark of Thermo Fisher Scientific Inc.