ショッピングカート
CD274 (PD-L1, B7-H1) Monoclonal Antibody (MIH5), Super Bright™ 436, eBioscience™

CD274 (PD-L1, B7-H1) Monoclonal Antibody (MIH5), Super Bright™ 436, eBioscience™

種類 62-5982-80
通常価格 本製品は国内取り扱い不可製品です。誠に申し訳ございません。 本製品は国内取り扱い不可製品です。誠に申し訳ございません。
お問い合わせ:cytek_japan_ifc@cytekbio.com
task_alt カートに追加されました。
カートを見る または ショッピングを続ける
説明

PRODUCT DETAILS

Host: Rat

Isotype: IgG2a, lambda

Clonality: Monoclonal

Clone: MIH5

Format: Super Bright™ 436

Reactivity: Mouse

Application: Flow Cytometry

Tested Dilution: 0.25 µg/Test

Concentration: 0.2 mg/mL

Storage: 4° C, store in dark, DO NOT FREEZE!

Formulation: PBS, pH 7.2, containing 0.09% sodium azide

Purification: Affinity chromatography

Data Sheet: TDS


Specific Information

Description: The MIH5 monoclonal antibody reacts with mouse CD274, also known as B7-H1 or PD-L1. B7-H1, a member of the B7 family, has a predicted molecular weight of approximately 40 kDa and belongs to the Ig superfamily. B7-H1 is expressed on a majority of leukocytes including T, B, NK and DC. B7-H1 is a ligand for PD-1. Interaction of PD-1 with either PD-L1 (B7-H1) or PD-L2 (B7-DC) results in inhibition of T and B cell responses. MIH5 is reported to be a blocking antibody.

Applications Reported: This MIH5 antibody has been reported for use in flow cytometric analysis.

Applications Tested: This MIH5 antibody has been tested by flow cytometric analysis of mouse splenocytes. This can be used at less than or equal to 0.25 µg per test. A test is defined as the amount (µg) of antibody that will stain a cell sample in a final volume of 100 µL. Cell number should be determined empirically but can range from 10^5 to 10^8 cells/test. It is recommended that the antibody be carefully titrated for optimal performance in the assay of interest.

Super Bright 436 can be excited with the violet laser line (405 nm) and emits at 436 nm. We recommend using a 450/50 bandpass filter, or equivalent. Please make sure that your instrument is capable of detecting this fluorochrome.

When using two or more Super Bright dye-conjugated antibodies in a staining panel, it is recommended to use Super Bright Complete Staining Buffer (Product # SB-4401) to minimize any non-specific polymer interactions. Please refer to the datasheet for Super Bright Staining Buffer for more information.

Excitation: 405 nm; Emission: 436 nm; Laser: Violet Laser

Super Bright Polymer Dyes are sold under license from Becton, Dickinson and Company.

 

For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.