{"product_id":"helios-monoclonal-antibody-22f6-efluor-450-ebioscience","title":"HELIOS Monoclonal Antibody (22F6), eFluor 450, eBioscience","description":"\u003cp\u003e\u003cstrong\u003ePRODUCT DETAILS\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eHost: \u003c\/b\u003e\u003cspan\u003eArmenian Hamster\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eIsotype: \u003c\/b\u003e\u003cspan\u003eIgG\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eClonality: \u003c\/b\u003e\u003cspan\u003eMonoclonal\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eClone: \u003c\/b\u003e\u003cspan\u003e22F6\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eFormat: \u003c\/b\u003e\u003cspan\u003eeFluor 450\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eReactivity: \u003c\/b\u003e\u003cspan\u003eCa, Hu, Ms\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eApplication: \u003c\/b\u003e\u003cspan\u003eFlow Cytometry\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eTested Dilution: \u003c\/b\u003e\u003cspan\u003e5 µL (0.03 µg)\/test\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eConcentration: \u003c\/b\u003e\u003cspan\u003e5 μL\/Test\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eStorage: \u003c\/b\u003e\u003cspan\u003e4°C, store in dark, DO NOT FREEZE!\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eFormulation: \u003c\/b\u003e\u003cspan\u003ePBS with BSA and 0.09% sodium azide; pH 7.2\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003ePurification: \u003c\/b\u003e\u003cspan\u003eAffinity chromatography\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eData Sheet: \u003c\/b\u003e\u003ca href=\"https:\/\/www.thermofisher.com\/order\/genome-database\/dataSheetPdf?producttype=antibody\u0026amp;productsubtype=antibody_primary\u0026amp;productId=48-9883-42\" target=\"_blank\"\u003eTDS\u003c\/a\u003e\u003c\/p\u003e \u003cbr\u003e\u003cp\u003e\u003cspan\u003e\u003cb\u003eSpecific Information\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003eDescription: This 22F6 monoclonal antibody reacts with human, mouse and canine Helios. Helios is a zinc-finger transcription factor first identified for its similarity to Ikaros. It is expressed in hematopoietic stem cells in both the embryo and adult mice. While the highest expression is found in regulatory T cells, Helios is not expressed in mature B cells, dendritic cells or myeloid cells. Helios can form a homodimer as well as heterodimerize with other Ikaros family members to regulate transcription. Eight isoforms of Helios exist, some of which possess a dominant-negative function that has also been found to be upregulated in lymphoid malignancies, including T-acute lymphoblastic leukemia.\u003c\/p\u003e\u003cp\u003e22F6 has been reported to cross react with rat Helios.\u003c\/p\u003e\u003cp\u003eApplications Reported: This 22F6 antibody has been reported for use in intracellular staining followed by flow cytometric analysis.\u003c\/p\u003e\u003cp\u003eApplications Tested: This 22F6 antibody has been pre-titrated and tested by intracellular staining and flow cytometric analysis of normal human peripheral blood cells using Foxp3 Fixation and Permeabilization Buffers (\u003ca href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/00-5521-00\"\u003eProduct # 00-5521-00\u003c\/a\u003e). Please see \u003ca href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/references\/protocols\/cell-and-tissue-analysis\/protocols\/staining-intracellular-antigens-flow-cytometry.html?cid=bid_pca_imm_r01_co_cp1600_pgm0000_intprotocol_0wm_tfs_il_edu_an_s00_\"\u003eBestProtocols®\u003c\/a\u003e Section (Staining intracellular Antigens for Flow Cytometry) for staining protocol (refer to Protocol B: One-step protocol for intracellular (nuclear) proteins. This can be used at 5 µL (0.03 µg) per test. A test is defined as the amount (µg) of antibody that will stain a cell sample in a final volume of 100 µL. Cell number should be determined empirically but can range from 10^5 to 10^8 cells\/test.\u003c\/p\u003e\u003cp\u003eeFluor® 450 is an alternative to Pacific Blue®. eFluor® 450 emits at 445 nm and is excited with the Violet laser (405 nm). Please make sure that your instrument is capable of detecting this fluorochrome.\u003c\/p\u003e\u003cp\u003eExcitation: 405 nm; Emission: 445 nm; Laser: Violet Laser.\u003c\/p\u003e\u003cp\u003eFiltration: 0.2 µm post-manufacturing filtered.\u003c\/p\u003e\u003cp\u003e \u003c\/p\u003eFor Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.","brand":"Cytek Biosciences","offers":[{"title":"100 Tests","offer_id":43198612799524,"sku":"48-9883-42","price":508.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1654\/6801\/files\/48-9883-42_HELIOS_Flow_1-20170119083539.jpg?v=1769203739","url":"https:\/\/cytekbio.com\/ja\/products\/helios-monoclonal-antibody-22f6-efluor-450-ebioscience","provider":"Cytek Biosciences","version":"1.0","type":"link"}